Wall-plug efficiency (WPE), also called radiant efficiency, is a measure of energy conversion efficiency defined as the ratio of the useful radiant (optical) output power of a device or system to the electrical power it draws from the mains supply — i.e., "at the wall plug." In equation form, it is the radiant flux (total output power) divided by the input electrical power, usually expressed as a percentage.
Scope and definition
The concept is used most frequently in optics and photonics, where it quantifies how effectively a light source converts electricity into light. The term is applied to:
- Laser systems, including laser diodes, diode-pumped solid-state lasers, and fiber lasers.
- Light-emitting diodes (LEDs), where it represents the fraction of electrical power converted to optical power emerging from the device.
- Other electrically driven emitters, such as terahertz quantum cascade lasers.
A strict reading of the term requires that electrical power be measured at the wall outlet, so that the figure includes losses in the power supply and the power consumed by any cooling system. In practice, however, many reported values are calculated from the electrical power delivered to the laser or emitter itself, ignoring power-supply losses — a convention that should be noted when comparing figures from different sources.
Related quantities
Wall-plug efficiency is distinct from, but related to, several other efficiency metrics:
- Slope efficiency — the differential ratio of output power increase to input power increase above threshold.
- External quantum efficiency — the ratio of emitted photons to injected electrons.
- Luminous efficacy of a source — a photometric measure that weights output according to the spectral sensitivity of human vision; this is sometimes called "wall-plug efficacy."
For lasers, the wall-plug efficiency is bounded in part by the quantum defect, a fundamental limit arising from the energy difference between pump and emitted photons.
Typical values
Reported wall-plug efficiencies vary widely by device class:
- Direct-diode laser systems can exceed 60%, with individual high-power laser diodes reported above 70% at certain wavelengths under laboratory conditions.
- High-power fiber lasers used as brightness converters can reach roughly 50% in favorable cases.
- Diode-pumped solid-state lasers (e.g., Nd:YAG) are commonly on the order of 25%, with thin-disk Yb:YAG systems exceeding 30%.
- Argon-ion lasers, and titanium–sapphire lasers pumped by them, typically have wall-plug efficiencies around or below 0.1%.
Significance
For high-power light sources, wall-plug efficiency is an important practical figure of merit. A higher efficiency reduces electrical power consumption and the waste heat that must be removed, which in turn lowers demands on electrical and cooling infrastructure and can reduce overall system size. Efficiency is also relevant for low-power devices in applications with tight power budgets, such as optical telecommunications transmitters and space-based instruments.
References and sources
The term is established in the technical literature, including works on solid-state laser efficiency (e.g., N. P. Barnes, IEEE J. Sel. Top. Quantum Electron., 2007) and standard laser engineering texts (e.g., W. Koechner, Solid-State Laser Engineering). It appears in reference resources such as Wikipedia and the RP Photonics Encyclopedia.
Reliable encyclopedic sources exist for this term; no "[Insufficient Encyclopedic Information]" designation is required.