The standard hydrogen electrode (SHE) is a reference electrode used in electrochemistry to define the standard electrode potential scale. It is assigned a potential of exactly 0.000 V at all temperatures when all species involved are at their standard states.

Construction and operation

  • Electrode composition: A platinum metal plate or a platinum black surface provides a catalytic surface for the reversible oxidation and reduction of hydrogen.
  • Electrolyte: An aqueous solution of a strong acid (commonly perchloric acid, sulfuric acid, or hydrochloric acid) adjusted so that the activity of hydrogen ions (H⁺) is unity (a_{H⁺}=1). This corresponds to a molar concentration of 1 M for the acid, assuming ideal behavior.
  • Hydrogen gas: Molecular hydrogen is bubbled over the electrode at a pressure of 1 atm (101.325 kPa). The gas is in equilibrium with the solution.
  • Reaction: The electrode facilitates the half‑reaction
    $$ \text{2 H}^{+} + 2 e^{-} \rightleftharpoons \text{H}_2(g) $$ under the specified standard conditions. Under these conditions, the Gibbs free energy change for the reaction is defined as zero, resulting in an electrode potential of 0 V by convention.

Role in electrochemical measurements

  • Reference point: By defining the SHE potential as zero, all other electrode potentials are expressed relative to this standard. The potentials measured versus the SHE are called standard electrode potentials (E°).
  • Use in tables: Standard reduction potentials tabulated in textbooks and databases are referenced to the SHE.
  • Calibration: Practical laboratory reference electrodes (e.g., saturated calomel electrode, silver/silver chloride electrode) are calibrated against the SHE or a primary standard cell traceable to the SHE.

Practical considerations

  • The SHE is rarely used directly in routine laboratory work because maintaining a pure hydrogen atmosphere at exactly 1 atm and an activity of H⁺ of one is experimentally demanding.
  • Alternative reference electrodes that are easier to handle but have well‑characterized potentials relative to the SHE are commonly employed.
  • The International Union of Pure and Applied Chemistry (IUPAC) recommends using the notation “E°(X) = E(X) – E(SHE)” to indicate a potential measured relative to the SHE.

Historical context

  • The concept of a universal reference electrode was introduced in the early 20th century to provide a common basis for comparing electrochemical data.
  • The SHE became the internationally accepted reference during the 1930s, and its definition has been retained in the IUPAC Green Book of physical constants.