The Rankine cycle is a thermodynamic cycle that converts heat into mechanical work while undergoing phase change. It is the fundamental operating cycle of most power plants, including those fueled by coal, nuclear energy, natural gas, and concentrated solar power. The cycle is named after William John Macquorn Rankine, a Scottish polymath and pioneer of thermodynamics.
Basic Components and Processes
The ideal Rankine cycle consists of four steady-state, steady-flow processes executed in four distinct components:
- Isentropic Compression (Pump): Saturated liquid water is pressurized from the condenser pressure to the boiler pressure. Because liquid water is nearly incompressible, the work input required by the pump is relatively small compared to the turbine work output.
- Constant-Pressure Heat Addition (Boiler/Steam Generator): The high-pressure liquid enters the boiler, where it is heated to saturation temperature, vaporized completely, and often superheated to a high temperature. Heat is transferred from an external source (combustion, nuclear fission, etc.) at constant pressure.
- Isentropic Expansion (Turbine): The high-pressure, high-temperature steam expands through a turbine, producing shaft work. The pressure and temperature drop significantly. In the ideal cycle, this expansion is reversible and adiabatic (isentropic).
- Constant-Pressure Heat Rejection (Condenser): The exhaust steam (typically a saturated liquid-vapor mixture) enters the condenser, where it rejects heat to a cooling medium (cooling water or air) and condenses back into saturated liquid at constant pressure.
Thermodynamic Analysis
The thermal efficiency ($\eta_{th}$) of the ideal Rankine cycle is defined as the ratio of net work output to heat input:
$$ \eta_{th} = \frac{W_{net}}{Q_{in}} = \frac{W_{turbine} - W_{pump}}{Q_{boiler}} = 1 - \frac{Q_{out}}{Q_{in}} $$
On a Temperature-Entropy (T-s) diagram, the cycle forms a shape resembling a right-leaning trapezoid or a "Moran" shape if superheated. The area enclosed by the cycle represents the net work output.
Deviations from Ideality (Actual Cycle)
Real Rankine cycles deviate from the ideal due to irreversibilities:
- Fluid Friction: Pressure drops in the boiler, condenser, and piping.
- Heat Loss: Heat transfer from components to the surroundings.
- Turbine and Pump Inefficiencies: Actual expansion and compression processes are not isentropic. Isentropic efficiencies ($\eta_t$, $\eta_p$) are used to quantify these deviations (typically 80–90% for large turbines, 60–85% for pumps).
Common Modifications to Improve Efficiency
Several modifications are standard in modern power plants to increase the average temperature of heat addition or decrease the average temperature of heat rejection:
- Superheat Rankine Cycle: Steam is heated above saturation temperature. This increases turbine work output, improves efficiency, and reduces moisture content at the turbine exit (protecting blades from erosion).
- Reheat Cycle: Steam expands through a high-pressure turbine, returns to the boiler for reheating at constant pressure, then expands through a low-pressure turbine. This significantly reduces moisture content at the final turbine stages and moderately improves efficiency.
- Regenerative Cycle (Feedwater Heating): Steam is extracted (bled) from various turbine stages to preheat the feedwater before it enters the boiler. This raises the average temperature of heat addition. Practical plants use a combination of open (direct contact) and closed (surface) feedwater heaters.
- Supercritical and Ultra-Supercritical Cycles: Operating the boiler at pressures above the critical point of water (22.064 MPa). There is no distinct phase change (boiling), eliminating the latent heat barrier and allowing higher average heat addition temperatures, yielding efficiencies exceeding 45% (up to 50% for ultra-supercritical with advanced materials).
Working Fluids
While water/steam is the dominant working fluid due to its abundance, low cost, non-toxicity, and favorable thermophysical properties (high latent heat, high critical temperature), other fluids are used in Organic Rankine Cycles (ORC). ORCs utilize organic fluids (refrigerants, hydrocarbons, siloxanes) with lower boiling points and higher molecular weights, making them suitable for low-grade heat sources (geothermal, biomass, industrial waste heat, solar thermal) typically below 300–400°C.
Applications
The Rankine cycle is the backbone of global electricity generation. As of the early 21st century, the vast majority of the world's electricity is produced by Rankine cycle plants (steam turbines). It is also used in marine propulsion (nuclear-powered naval vessels, LNG carriers) and industrial combined heat and power (CHP) systems.