WIPIVERSE All articles

RadBall

The RadBall is a 140-millimetre (5.5-inch) diameter deployable, passive, non-electrical gamma hot-spot imaging device that offers a 360-degree view of its deployment area. It was developed by the UK's National Nuclear Laboratory (NNL).

Design and Operation

The device consists of two main components: an inner spherical core made of a radiation-sensitive material, and an outer tungsten-based collimation sheath. The inner core changes colour when exposed to gamma radiation. When deployed in a radioactive environment, the collimation sheath preferentially allows gamma radiation to pass through its collimation holes, depositing tracks within the inner core. These tracks are later analysed to produce a three-dimensional visualisation of the radioactive environment, predicting both source location and intensity.

The device requires no electrical supply or communication link and can be deployed remotely, eliminating radiation exposure to personnel. Its target dose range is between 2 and 5,000 rads (20 mGy to 50 Gy).

Deployment Process

The radiation mapping service involves six steps: (1) placing the device in a contaminated area with known position and orientation, (2) leaving it in situ for dose uptake, (3) retrieving the device, (4) removing the radiation-sensitive core from the collimator, (5) optically scanning the core to digitise the information, and (6) interpreting the data to produce a final visualisation. If two devices are deployed at different locations, triangulation can be used to more precisely predict the location of radiation sources.

Deployment History

The RadBall technology has been successfully deployed at several nuclear sites:

  • Savannah River Site, USA – Initial lab-based testing and deployment in a contaminated Hot Cell.
  • Hanford Site, USA – First successful underwater deployment of the technology to locate submerged radiological hazards.
  • Oak Ridge National Laboratory, USA – Trials demonstrating the ability to locate, quantify, and characterise radiological hazards in multiple Hot Cells.
  • Sellafield Site, UK – First instance of triangulation using three devices, successfully locating and quantifying approximately a dozen radioactive sources.

Advantages

Compared to alternative technologies (such as GM-based detectors on manipulator arms or shielded gamma cameras), the RadBall offers directional awareness, the ability to distinguish nearby sources, a compact size, low weight, no need for a power or data umbilical, and lower financial risk if the equipment becomes contaminated.

Browse

More topics to explore

    Browse all articles