Process duct work is an established engineering concept referring to the system of large ducts that conveys large volumes of hot, dusty air from processing equipment to other process equipment, such as mills, baghouses, cyclones, and fans, primarily in industrial facilities. It is distinguished from conventional HVAC ductwork by its scale, operating conditions, and structural design requirements.
Overview
Process duct work is used in industrial settings to transport air or gas streams containing dust, heat, and process byproducts between pieces of processing equipment. It may be round or rectangular in cross-section. While round duct work generally costs more to fabricate than rectangular duct work, it requires fewer stiffeners and is often favored in many applications because its geometry better resists bending between supports.
Process duct work operates under a wide range of conditions. The air or gas it carries may be at ambient conditions or at elevated temperatures up to roughly 900 °F (482 °C), with some systems operating as high as 1,000 °F (538 °C). Duct sizes range from roughly 2 feet (0.6 m) in diameter to 20 feet (6 m) in diameter, and rectangular ducts may reach dimensions of approximately 20 by 40 feet (6 by 12 m).
Dust Loading
A distinctive characteristic of process duct work is its exposure to internal dust accumulation. Depending on duct slope, large process duct work may fill with settled dust to up to 30% of its cross-section. This accumulated dust can weigh 2 to 4 tons per linear foot, imposing significant structural loads that must be accounted for in design.
To minimize dust buildup, process ducts are typically sloped at angles at or above the dust's angle of repose, often 30 degrees or steeper. Minimum gas carrying velocities vary by industry and material: approximately 2,800 feet per minute for lime, 3,200 feet per minute for cement, and 4,200 feet per minute for lead dust.
Design Considerations
There is no single comprehensive design reference for process duct work. The ASCE publication Structural Design of Air & Gas Ducts for Power Stations and Industrial Boiler Applications provides general guidance, but engineers typically combine multiple references, including Roark's Formulas for Stress and Strain, US Steel plate design literature, SMACNA standards, and Tubular Steel Structures references.
Key design factors include:
- Duct dead loads, including plate weight with allowances for stiffeners (typically 15% for cement plant ductwork, but 50% to 100% for rectangular power plant ductwork).
- Internal dust loads, which vary with duct slope: 25% of cross-section for slopes of 0–30 degrees, 15% for 30–45 degrees, 5% for 45–85 degrees, and a 2-inch coating for slopes exceeding 85 degrees.
- Duct suction pressure loads, typically designed for 25 to 40 inches of water pressure, which can cause side-wall collapse in larger ducts.
- Wind and seismic loads.
- Thermal expansion, as ducts are assumed to reach internal gas temperatures; at 1,000 °F, ductwork may grow approximately 5/8 inch per 10 feet of length, requiring expansion joints at equipment flanges.
Round vs. Rectangular Duct Work
Round duct work is common in the cement, lime, and lead industries. Its plate design is based on diameter-to-thickness ratios, with ovaling and support ring stiffeners typically spaced at roughly three diameters or 20-foot centers. Round ducts larger than about 6 feet 6 inches in diameter typically require support ring stiffeners. Round duct work is generally more material-efficient than rectangular duct work, requiring lighter intermediate stiffeners (approximately 5% of plate weight in cement plants).
Rectangular duct work is more common in power plants, where it can be significantly larger. Its design is based on width-to-thickness ratios, and because flat plate bends under load, stiffeners must be spaced more closely (often around 2.5 feet on center for cement plant ductwork). Rectangular duct stiffener weights can be 15–20% of plate weight in cement plants and 50% or more in power plants.
Materials and Temperature Effects
For mild carbon steels (ASTM A36), design yield stress decreases with temperature: approximately 84% of room-temperature value at 300 °F, 77% at 500 °F, and 71% at 700 °F. Above roughly 800 °F, mild carbon steel may warp, and materials such as Corten or stainless steel (e.g., ASTM A304 or A316L) may be used. Corten steel retains suitable properties up to about 1,100 °F.
Corrosion and Wear
Moisture condensation in duct work can absorb carbon dioxide and other gas-stream components, becoming corrosive to low-carbon steel. Mitigation approaches include duct insulation, specialty steels, and internal coatings. For abrasive dusts, such as cement clinker dust (more abrasive than sand), refractory linings anchored with V-anchors are commonly used, sometimes with ceramic tiles.
Expansion Joints
Duct segments are typically separated by fabric or metal expansion joints. Fabric joints are often preferred because they generally cost about 40% less than metal joints and impose minimal loads on duct segments. Fabric joint service life is roughly five years under field conditions.
Pressure Drop and Energy Considerations
Minimizing pressure drop is important because duct inefficiency directly increases operating costs. In cement plants, 60–80% of pressure drop occurs in process equipment (baghouses, mills, cyclones) rather than in the ducting itself. Elbow radius is typically 1.5 to 2 times the duct diameter to minimize turbulence, and transition side slopes are usually 10 to 30 degrees. Fans used with large process duct work can range from 250 to 4,000 horsepower.
Explosion Protection
Duct work associated with coal mills, coke grinding, and some grain facilities may be subject to explosive dust hazards. Such duct work is typically designed for 50 psi internal pressure and fitted with explosion relief vents.
References
- ASCE, Structural Design of Air & Gas Ducts for Power Stations and Industrial Boiler Applications
- Roark & Young, Formulas for Stress & Strain
- US Steel, Plate Structures (Volumes I & II)
- SMACNA standards
- AISC steel design references
- Lincoln Arc Welding, Tubular Steel Structures (Troitsky)
- API 560