Permissible stress design (PSD), also known as allowable stress design (ASD) or working stress design (WSD), is a design philosophy used in structural and mechanical engineering. Under this method, a structural member is proportioned so that the stresses calculated under normal service (working) loads do not exceed a predefined allowable stress value. The allowable stress is typically derived from the material's yield or ultimate strength divided by a factor of safety, and the analysis assumes linear elastic material behavior.

Definition and principles

In permissible stress design, the stresses developed in a structure due to unfactored service loads—such as dead, live, wind, and seismic forces—are compared against allowable limits. These allowable stresses are obtained by applying a factor of safety to material strength properties. The method ensures that the structure remains within the elastic range, preventing yielding and excessive deformation under ordinary operating conditions.

The "factor" applied is sometimes called a factor of safety, though it is not strictly identical to a safety factor because it also incorporates allowances for local stresses, manufacturing imperfections, and other effects that are not explicitly calculated.

Applications

The approach applies to a range of materials, including steel, concrete, timber, and masonry, and to various structures such as buildings, bridges, pressure vessels, and offshore platforms. In mechanical engineering—for example, in the design of pressure equipment—the method uses actual predicted operating loads to calculate stress and deflection, which are then compared with allowable values that provide margins against failure mechanisms such as leakage, yield, buckling, brittle fracture, fatigue, and vibration.

In some national standards, the permissible stress method is referred to as the working stress method, because the predicted stresses are the unfactored stresses expected during operation (for example, in the Australian standards AS1210 and AS3990).

History and development

Permissible stress design emerged in the 19th and early 20th centuries as structural engineering moved from empirical practices toward analytical methods based on elasticity theory. The method was formalized in early building codes, notably the American Institute of Steel Construction (AISC) specification of 1923, which established standardized allowable stresses for steel-framed buildings. Subsequent AISC editions refined provisions for buckling, connections, and fatigue while retaining the underlying elastic philosophy. The 1906 San Francisco earthquake also influenced the development of lateral-force provisions and increased allowable stresses for transient loads such as wind and seismic forces.

By the mid-20th century, permissible stress design dominated civil engineering codes globally, including for reinforced concrete and timber. However, its reliance on a single global factor of safety for all sources of uncertainty—loads, materials, and fabrication—drew criticism for inconsistent reliability in variable-load scenarios.

Current status

In structural engineering, permissible stress design has largely been replaced internationally by limit state design (also known as ultimate stress design, or in the United States as Load and Resistance Factor Design, LRFD). This transition occurred in the United States with the introduction of the AISC LRFD specification in 1986, and internationally through limit state codes such as the Eurocodes beginning in the 1990s.

Despite this, permissible stress design remains in use in certain contexts. In the United States, wood and steel are still frequently designed using allowable stress design, and LRFD is more commonly taught in university programs. Suspension bridges shifted from allowable stress design to limit state design in the 1960s. The method also persists in niche applications such as temporary works, certain offshore structures, and older code-compliant retrofits, as well as in some material standards (for example, the NDS for timber).

Distinction from ultimate design

Permissible stress design differs fundamentally from ultimate (limit state) design in how it treats loads and capacities. The permissible stress method factors down the failure stress (comparing working stresses to reduced allowable stresses), whereas an ultimate design approach factors up the predicted loads for comparison against an ultimate failure limit. As a result, permissible stress design is generally more conservative against first yield but can produce larger or heavier members than modern limit state methods.