The matched Z-transform method (also known as the pole-zero matching method or equivalent impulse response invariance method for pole-zero mapping) is a technique used in digital signal processing and digital control systems to convert a continuous-time linear time-invariant (LTI) system, represented in the Laplace domain (s-plane), into a discrete-time LTI system represented in the Z-domain (z-plane).
Mapping Principle The method maps the poles and zeros of the analog transfer function $H(s)$ directly to the digital transfer function $H(z)$ using the relation: $$z = e^{sT}$$ where $T$ is the sampling period. Specifically:
- A pole or zero at $s = s_k$ in the s-plane maps to $z = e^{s_k T}$ in the z-plane.
- The factor $(s - s_k)$ in $H(s)$ becomes $(z - e^{s_k T})$ in $H(z)$.
- The gain of the digital filter is typically scaled to match the DC gain (frequency response at $\omega = 0$) or the gain at a specific frequency of the analog prototype.
Characteristics
- Stability Preservation: Since the left-half s-plane maps entirely inside the unit circle in the z-plane, a stable analog prototype always yields a stable digital filter.
- Frequency Response Distortion: The mapping $z = e^{sT}$ corresponds to $\omega = \Omega T$ only for the imaginary axis ($s = j\Omega$). However, because the mapping of the entire s-plane is not a simple linear frequency warp (unlike the Bilinear Transform), the frequency response of the resulting digital filter matches the analog prototype only at the specific frequencies of the mapped poles and zeros. Significant aliasing distortion generally occurs if the analog prototype has significant energy above the Nyquist frequency ($\pi/T$).
- No Aliasing Compensation: Unlike the Impulse Invariance method (which it resembles but differs from in gain scaling and handling of multiple-order poles), the Matched Z-transform does not inherently account for aliasing in the frequency domain summation sense; it is a direct algebraic substitution.
- Handling of Zeros at Infinity: Analog zeros at $s \to \infty$ (which occur when the numerator order is less than the denominator order) map to $z = 0$. If the analog system has more poles than zeros, the resulting digital system will have excess zeros at the origin (delay terms).
Comparison with Other Methods
- vs. Impulse Invariance: Both map poles via $z = e^{sT}$. Impulse invariance preserves the impulse response shape exactly (sampled), whereas Matched Z-transform preserves the pole-zero pattern algebraically. For systems with distinct poles, the transfer functions are identical up to a gain constant. For multiple-order poles, the methods yield different partial fraction expansions.
- vs. Bilinear Transform: The Bilinear Transform ($s = \frac{2}{T} \frac{z-1}{z+1}$) warps the frequency axis non-linearly to prevent aliasing but distorts the phase response and pole-zero locations relative to the analog prototype. The Matched Z-transform preserves the pole-zero geometry relative to the exponential mapping but suffers from aliasing.
Applications The method is primarily used when preserving the exact pole-zero locations (relative to the $e^{sT}$ mapping) is critical, such as in the discretization of analog controllers for digital implementation where the transient response characteristics (damping, natural frequency) associated with specific poles must be maintained. It is less common for general filter design (e.g., low-pass, high-pass) where the Bilinear Transform is preferred due to its aliasing-free property.