A magnetometer is an instrument that measures a magnetic field (B) or a magnetic dipole moment. Different types of magnetometers measure the direction, strength, or relative change of the magnetic field at a particular location. The compass, consisting of a magnetized needle whose orientation responds to an ambient magnetic field, is the simplest example of a magnetometer, measuring the direction of the Earth's magnetic field. Other magnetometers measure the magnetic dipole moment of a material such as a ferromagnet, for instance by recording the effect of that dipole on a current induced in a coil.

Units and quantities

Magnetic fields are vector quantities characterized by both strength and direction. In the International System of Units (SI), magnetic flux density B is measured in tesla; in the centimetre–gram–second (cgs) system it is measured in gauss, where one tesla equals 10,000 gauss. Measurements of the Earth's magnetic field are often quoted in nanotesla (nT), also called a gamma. The Earth's field varies from roughly 20,000 to 80,000 nT depending on location, temporal fluctuations are on the order of 100 nT, and variations due to magnetic anomalies can extend into the picotesla (pT) range. The term gaussmeter is sometimes reserved for instruments measuring fields greater than one millitesla (mT), while magnetometer is applied to instruments measuring fields below that level, though usage is not fully consistent.

History

The invention of the magnetometer is usually credited to Carl Friedrich Gauss in 1832; his instrument consisted of a permanent bar magnet suspended horizontally from a gold fibre, and the difference in oscillation periods of the magnetized and demagnetized bar allowed an absolute value for the strength of the Earth's field to be calculated. Earlier, more primitive instruments were developed by Christopher Hansteen in 1819 and by William Scoresby by 1823, the latter publishing a description of a "magnetimeter." Francis Ronalds and Charles Brooke independently invented magnetographs in 1846 that continuously recorded a magnet's movements photographically, and such instruments were used in global magnetic surveys. The gauss, the cgs unit of magnetic flux density, is named in Gauss's honour.

Types of measurement

There are two basic categories of magnetometer measurement:

  • Vector magnetometers measure one or more vector components of a magnetic field, relative to the spatial orientation of the device. Three orthogonal sensors are required to determine all three components.
  • Scalar or total-field magnetometers measure the magnitude of the vector magnetic field, not its direction.

Magnetometers may also be described as absolute (the field is determined from internal calibration or known physical constants of the sensor) or relative (measurements referenced to a fixed but uncalibrated baseline; also called variometers). Instruments may be further classified as stationary, portable or mobile, laboratory, or survey instruments, and as "DC" (quasi-static fields) or "AC" (fields varying faster than about 100 Hz). Magnetometers used to study the Earth's field may express the vector components in terms of declination (angle between the horizontal field component and true north) and inclination (angle between the field vector and the horizontal).

Principal sensor technologies

Fluxgate magnetometers consist of a magnetically susceptible core wrapped by drive and sense coils. An alternating current drives the core through cycles of magnetic saturation, continuously gating an external field in and out of the sense winding (hence "fluxgate") and inducing a signal whose principal frequency is twice the drive frequency. The fluxgate magnetometer was invented by H. Aschenbrenner and G. Goubau in 1936; a team at Gulf Research Laboratories led by Victor Vacquier later developed airborne fluxgate magnetometers. Fluxgates are comparatively affordable, rugged, and compact, and are widely used in compasses, gradiometers, and geophysical and archaeological prospecting.

Scalar atomic and nuclear-precession instruments include:

  • Proton precession magnetometers (PPMs), which measure the nuclear magnetic resonance (NMR) precession frequency of protons in the ambient field; because that frequency depends only on atomic constants and the field strength, accuracy can reach about 1 ppm. Sample rates for portable units are typically below one per second.
  • Overhauser effect magnetometers, which add free radicals to the measurement fluid so that a low-power radio-frequency field polarizes electron spins that couple to protons via the nuclear Overhauser effect, allowing lower power consumption and faster cycling than PPMs.
  • Optically pumped alkali-vapour magnetometers (caesium, rubidium, potassium), in which laser light optically pumps atoms in a vapour cell and the degree of transmitted light changes with the applied field. Caesium instruments are highly sensitive, and potassium instruments operate on a single narrow electron spin resonance line.
  • Metastable helium-4 scalar magnetometers, developed from the 1960s onward and subsequently selected for the European Space Agency's Swarm mission (launched 2013).

Hall-effect and magnetoresistive devices are solid-state sensors. Hall-effect sensors produce a voltage proportional to the applied field and are common in applications where field strengths are relatively large. Magnetoresistive devices, made of thin strips of a nickel–iron alloy such as Permalloy, change resistance with the field and can be mass-produced as integrated circuits.

SQUID magnetometers (superconducting quantum interference devices) exploit flux quantization in a superconducting loop and are extremely sensitive vector instruments, achieving noise levels as low as a few femtotesla per root hertz in commercial instruments. They require cryogenic cooling with liquid helium or liquid nitrogen. Spin-exchange relaxation-free (SERF) atomic magnetometers operate only in very low fields but can reach sensitivities below 1 fT·Hz⁻¹ᐟ² and have been investigated as replacements for SQUIDs where cryogenics are a drawback.

Laboratory magnetometry concerns the measurement of a sample's magnetization or magnetic moment, often as a function of temperature and applied field, to identify magnetic ordering (diamagnetic, paramagnetic, ferromagnetic, antiferromagnetic, and others) and phase transitions. Techniques include SQUID magnetometry, inductive pickup coils, vibrating-sample magnetometry (VSM), pulsed-field magnetometry, torque magnetometry, Faraday force magnetometry, optical magnetometry (including the magneto-optic Kerr effect and Faraday rotation), alternating-gradient magnetometry, and A.C. susceptometry. Magnetographs are magnetometers that continuously record data over time, typically displayed as magnetograms.

Magnetic gradiometers use two or more magnetometers with sensors separated by a fixed distance, subtracting their readings to obtain the field gradient. This arrangement compensates for temporal variation of the Earth's field and for some sources of interference, and enhances shallow anomalies, making gradiometers useful in archaeology, unexploded ordnance detection, and utility location.

Performance specifications

Performance is commonly described by sample rate, bandwidth, resolution, absolute error, drift, thermal stability (expressed as a temperature coefficient in nT per degree Celsius), noise (in nT/√Hz), sensitivity (the larger of noise or resolution), heading error (change in reading with orientation in a constant field), dead zone (an angular region in which measurement is poor or absent; experienced to some degree by optically pumped, proton-free precession, and Overhauser instruments), and gradient tolerance (the ability to measure reliably in the presence of a field gradient).

Applications

Magnetometers are used to measure the Earth's magnetic field and its anomalies; in geophysical, archaeological, and engineering surveys; in mineral, coal, and oil exploration; to locate buried or submerged ferrous objects such as unexploded ordnance, pipelines, shipwrecks, and utility infrastructure; in directional drilling and drill guidance; and in aircraft attitude and heading reference systems. Military uses include magnetic anomaly detection for submarines, triggering mechanisms in magnetic mines, and sea-floor arrays; several countries classify the more sensitive magnetometers as controlled military technology. Magnetometers are flown on spacecraft for planetary and interplanetary field measurements, with examples including the Mariner, Cassini–Huygens, MESSENGER, Juno, and Swarm missions and the Pioneer 10 and 11 helium vector magnetometers. Miniaturized MEMS and three-axis magnetometers are widely embedded in smartphones for compass and orientation functions, and magnetometers are used in magnetoencephalography (MEG) and magnetocardiography to record weak biomagnetic fields, with optically pumped sensors enabling wearable, room-temperature systems. Other applications include anti-lock braking sensors, mechanical stress monitoring in ferromagnetic materials, accelerator physics, auroral and space-weather monitoring via the K-index, and magnetic navigation research.