Lugeon is a unit and an associated in-situ test method used in engineering geology and geotechnical engineering to quantify the water permeability and hydraulic conductivity of bedrock resulting from fractures and discontinuities. The unit is named after Maurice Lugeon (1870–1953), a Swiss geologist who first formulated the method in 1933. The test is also known as the packer test or water pressure test.
Definition of the unit
A Lugeon (symbol Lu) is defined as a steady-state water loss of one litre per minute per metre of borehole section, measured at an effective (over-)pressure of 1 MPa (10 bar, approximately 10 kg/cm²). Formally:
- 1 Lu = 1 L/min per metre of test section at an over-pressure of 1 MPa.
The unit consequently expresses an empirical measure of water absorption of a rock mass rather than an intrinsic material property. Because flow through jointed rock is dominated by fracture networks, the Lugeon value reflects the combined influence of joint connectivity, aperture, infilling and the erodibility of that infilling.
The Lugeon test
The Lugeon test is an in-situ, constant-head (constant-pressure) injection test performed within a borehole drilled into rock. A section of the hole is isolated between inflatable packers, and water is injected through a pipe under controlled pressure while the flow rate is measured with a water meter and the pressure recorded with a gauge. A typical procedure involves applying a sequence of increasing then decreasing pressure stages (commonly five stages), each held for a defined interval such as ten minutes, so that the relationship between pressure and flow can be assessed.
Results from each stage are used to compute the Lugeon value, typically taking the mean flow rate and pressure, and hydraulic conductivity may then be estimated using relations based on Darcy's law and the assumption of laminar flow. Deviations from a linear pressure–flow relationship are used to classify the behaviour of the rock mass, for example indicating joint filling, washout or elastic opening of fractures (often described through so-called "Lugeon types").
Applications
The primary engineering applications of the Lugeon test include:
- Assessing the in-situ permeability of rock masses for dam foundations, tunnels and other structures.
- Establishing grouting criteria and evaluating the effectiveness of grouting programmes (a common design threshold for grout curtains is on the order of a few Lugeon units).
- Estimating hydraulic conductivity where the test does not directly yield the conventional permeability coefficient, but provides a quantitative comparison of in-situ permeabilities.
Typical interpretive ranges associate low Lugeon values with tight, well-cemented rock and progressively higher values with increasingly open or weathered jointing.
Origin and naming
Maurice Lugeon was a Swiss geologist and pioneer of nappe tectonics who provided one of the first comprehensive interpretations of the Alps; he was a pupil of Eugène Renevier. The permeability test that bears his name was formulated in 1933 and has since been standardized or recommended by several bodies, including the International Society for Rock Mechanics and Rock Engineering (ISRM) and ASTM (e.g., ASTM D4630 for related low-permeability in-situ constant-head injection testing).
Standards and reference literature
Published treatments of the method include early interpretive work by Lancaster-Jones (1975) and Houlsby (1976) on routine interpretation of the Lugeon water test, Pearson and Money (1977) on improvements to the packer permeability test, and later suggested methods issued under ISRM auspices. These sources form the principal basis for contemporary practice and interpretation.