Definition
Electrolysed water is water that has been subjected to an electrolysis process, resulting in the formation of distinct chemical species with altered pH and redox potentials. The process typically yields an acidic (oxidizing) stream and an alkaline (reducing) stream, each possessing properties different from the original neutral water.
Production Process
- Electrolysis Cell: A sealed cell containing two electrodes (commonly made of titanium coated with noble metals such as platinum or ruthenium) is filled with a dilute electrolyte solution, often sodium chloride (NaCl) or other salts.
- Electrical Current: Direct current (DC) is applied across the electrodes.
- Cathodic Reaction (negative electrode): Water reduction produces hydrogen gas and hydroxide ions, raising the pH of the cathodic stream (alkaline water).
- Anodic Reaction (positive electrode): Oxidation of chloride ions generates hypochlorous acid (HOCl), chlorine gas, and other oxidative species, lowering the pH of the anodic stream (acidic water).
- Separation: The two streams are often separated and collected for specific applications.
Typical Characteristics
| Property | Acidic Stream (oxidizing) | Alkaline Stream (reducing) |
|---|---|---|
| pH | 2–3 | 10–12 |
| Redox Potential (ORP) | +800 to +1200 mV | –400 to –800 mV |
| Dominant Species | HOCl, Cl₂, O₃, H₂O₂ | OH⁻, H₂, Na⁺ (if NaCl used) |
| Appearance | Clear, often slightly yellow | Clear, colorless |
Primary Uses
-
Disinfection and Sanitation
- The acidic stream’s high oxidation‑reduction potential and presence of hypochlorous acid make it effective against bacteria, viruses, and fungi. It is employed in food‑processing facilities, hospitals, and water treatment plants.
-
Cleaning and Degreasing
- Alkaline electrolysed water dissolves organic soils, oils, and greases, useful for industrial cleaning, laundry, and surface preparation.
-
Agricultural Applications
- Foliar sprays of electrolysed water have been investigated for disease control and growth promotion in horticulture.
-
Medical and Dental Fields
- Low‑concentration acidic electrolysed water is sometimes used as an adjunctive irrigant in wound care and oral hygiene, owing to its antimicrobial activity without the harshness of conventional disinfectants.
-
Food Safety
- Acidic electrolysed water is applied to fresh produce, poultry, and seafood to reduce microbial load while preserving sensory qualities.
Safety and Regulatory Considerations
- Residues: When generated from sodium chloride, the acidic stream contains low concentrations of chlorine‑derived compounds. Proper dilution and ventilation are required to avoid irritation.
- Corrosion: High oxidation potentials can corrode certain metals; material compatibility must be evaluated for equipment.
- Regulation: In many jurisdictions, electrolysed water is regulated as a disinfectant or cleaning agent. Approval processes (e.g., EPA in the United States, EU Biocidal Products Regulation) assess efficacy and safety data.
Efficacy Evidence
- Numerous peer‑reviewed studies demonstrate that acidic electrolysed water achieves ≥5‑log reductions of Escherichia coli, Salmonella spp., and Staphylococcus aureus under laboratory conditions.
- Comparative trials often show comparable or superior performance to conventional chlorine solutions at lower active chlorine concentrations, reducing the risk of chlorination by‑products.
Limitations and Challenges
- Stability: Oxidizing species (e.g., HOCl) decay over time, reducing antimicrobial potency; fresh generation or on‑site production is typically required.
- pH Sensitivity: The antimicrobial efficacy of hypochlorous acid is optimal near pH 5–6; excessive alkalinity can diminish activity.
- Cost of Equipment: High‑quality electrode materials and power supplies represent an upfront investment, though operating costs are generally low because only water and modest amounts of salt are needed.
Research Directions
- Development of electrode coatings to extend lifespan and improve energy efficiency.
- Exploration of alternative electrolytes (e.g., potassium lactate) to tailor the chemical profile of the streams.
- Integration of electrolysed water generation into closed‑loop systems for sustainability in industrial processes.
Conclusion
Electrolysed water, produced through controlled electrolysis of dilute saline solutions, yields acidic and alkaline streams with distinct chemical and physicochemical properties. These streams find widespread use as disinfectants, cleaning agents, and in various industrial and clinical contexts, supported by a substantial body of scientific literature documenting their efficacy and safety when properly applied.