The coefficient of utilization (CU) is a term employed primarily in lighting engineering to quantify the efficiency with which luminous flux emitted by a lighting fixture is delivered to a designated illumination area, such as a work plane. It is defined as the ratio of the luminous flux that actually reaches the target surface to the total luminous flux produced by the source:
$$ \text{CU} = \frac{\Phi_{\text{useful}}}{\Phi_{\text{total}}} $$
where
- $\Phi_{\text{useful}}$ is the luminous flux (in lumens) incident on the intended illuminated area, and
- $\Phi_{\text{total}}$ is the total luminous flux emitted by the luminaire.
The coefficient of utilization depends on several factors, including:
- Room geometry – dimensions of the space, ceiling height, and the shape of the room influence the distribution of light.
- Surface reflectances – the reflectivity of walls, ceilings, and floors affects how much light is redirected toward the work plane.
- Luminaire characteristics – the photometric distribution of the fixture (e.g., Type I, II, III) determines the directionality of the emitted light.
In practice, lighting designers use CU values provided by manufacturers for specific luminaires in standard room configurations. These values are incorporated into lighting calculations, such as determining the number of fixtures required to achieve a target illuminance level (lux) on a work plane, according to formulas like:
$$ N = \frac{E \times A}{\Phi_{\text{lamp}} \times \text{CU} \times \text{MF}} $$
where
- $N$ is the number of luminaires,
- $E$ is the desired illuminance,
- $A$ is the area to be illuminated,
- $\Phi_{\text{lamp}}$ is the luminous flux per lamp, and
- $\text{MF}$ is the maintenance factor accounting for lumen depreciation over time.
The CU is distinct from, but related to, the utilization factor, which sometimes refers to the proportion of a building’s floor area that is actually occupied or used, a concept common in real‑estate and facilities management. In lighting contexts, the terms are often used interchangeably, though “coefficient of utilization” is more specific to photometric performance.
Because the CU varies with room conditions and luminaire design, designers frequently employ lighting design software or reference tables to select appropriate fixtures and predict lighting performance accurately.