Beta is a time signal service operating in the very low frequency (VLF) range in Russia, operated by the Russian Navy and controlled by the All-Russian Scientific Research Institute for Physical-Engineering and Radiotechnical Metrology (VNIIFTRI). The service provides precise time and frequency synchronization through a network of six transmitter stations that take turns transmitting time signals and other communications.
Overview
Beta transmits signals on frequencies in the 20–26 kHz VLF band, including 20.5, 23.0, 25.0, 25.1, and 25.5 kHz. The 25.0 kHz carrier, used at the start of each transmission session, is modulated with Morse code station identification and a time code. The remaining frequencies carry unmodulated carriers precisely phase-locked to the UTC(SU) time scale. No time code is transmitted during the final portion of each session.
Each transmitter conducts one or two scheduled transmission sessions per day, each lasting 31 to 41 minutes depending on the station, for a total of eight sessions across a 24-hour period. The transmitters are estimated to operate at approximately 1000 kW, achieving 30–50 kW effective isotropic radiated power (EIRP); the difference is attributed to the low efficiency of antennas at these frequencies, which are physically much smaller than the corresponding wavelength (roughly 12 km at 25 kHz).
Station network
The Beta network comprises six transmitter sites:
| Callsign | Location |
|---|---|
| RJH63 | Krasnodar |
| RJH69 | Vileyka (near Maladzyechna, Belarus) |
| RJH77 | Arkhangelsk |
| RJH86 | Bishkek (Kyrgyzstan) |
| RJH90 | Nizhny Novgorod (former German Goliath transmitter) |
| RAB99 | Khabarovsk |
Most of the stations were built during the 1970s. RJH63 and RAB99, constructed later, use a modified transmission format that includes a period of digital data transmission at 50 baud using ±50 Hz frequency-shift keying on 20.5 kHz.
Time code format
The Beta time code is composed of a series of carrier pulses:
- Each 100 ms, a 25 ms burst of carrier is transmitted.
- Each second, a 100 ms burst of carrier is transmitted.
- Each 10 s, a 1 s burst of carrier is transmitted.
- Each minute, a 10 s burst of carrier is transmitted.
The hour or date is not encoded in the signal.
Transmission schedule
A standard transmission hour begins with a transmitter tune-up period at low power, followed by unmodulated carrier, a Morse code call sign, carrier modulated with a 40 Hz square wave, and the time code on 25.0 kHz. The session then moves through 25.1, 25.5, 23.0, and 20.5 kHz carriers in sequence, ending approximately 47 minutes past the hour.
See also
- Very low frequency (VLF)
- Time signal service